> UPS системи SOCOMEC > STS системи за статичен трансфер SOCOMEC

STS системи за статичен трансфер SOCOMEC

IT-SWITCH Static transfer systems (STS)

APPLICATIONS

Permanent back-up for mission-critical, IT and telecommunications equipment within the INTERNET server field

 
ADVANTAGES

Dua
l power supply for redundancy

based on a double power supply system, the IT-SWITCH monitors voltage quality and automatically transfers the load from the priority source to a back-up source without any interruption.

Manual and automatic load transfer

Load transfer without source overlap

T
ransfer without disturbing the loads

Selection of priority source

The IT-SWITCH constantly monitors voltage quality supplied to critical loads. Should the chosen priority source fail, the IT-SWITCH automatically transfers the applications to the back-up supply in full safety and without any interruption.

A hot-swap version can be easily changed without interrupting the load by using manual by-passes. The IT- SWITCH has been especially designed for easy installation in the most effective place, i.e. close to mission-critical loads.




DIMENSIONS

 

rating* (A)

width (mm)

depth (mm)

height (mm)

 IT SWITCH HA

16

446 (19")

310

 131 (3U)

 IT SWITCH HA-E

16 and 20

484 (19")

400

 133 (3U)

* single-phase

 

INTEGRATION

 

IT SWITCH HA

IT SWITCH HA-E

extractible

 

High Availability Model B

 swappable Model E

INTEGRATION

 

 

Rack 19”

TRANSFER

 

 

Preferred source selection

Automatic transfer

Manual transfer

Changeover without source overlap

Synchronous and asynchronous changeover

Synchronous changeover only

Transfer lock on downstream fault

Lock on repetitive transfers

REMOTE MANAGEMENT

 

 

Command and control mimic panel

Dry contacts for information transfer

RS 485 JBUS serial port

Data log

CONNECTIONS AVAILABLE

 

 

IT SWITCH rack 19” - 16 A

 

 

Input and output on terminal blocks

 

Input and output on IEC 16 A sockets

IT SWITCH rack 19” - 20 A

 

 

Input and output on terminal blocks

 

MAINTENANCE

 

 

“Hot swap” pull out module

 

• 

Maintenance Bypass

 

• 

 

TECHNICAL DATA

Ratings

 rack model 16 A and 20 A

Voltage

single-phase 100/120/220/230/240 V

Input voltage tolerance

adjustable (factory setting +/- 15 %)

Frequency

50 or 60 Hz

Short circuit current capacity

20 / 15 In*

Admissible load crest factor

up to 4

Changeover switching

bipolar (phase/neutral)

Transfer mode

synchronous / asynchronous
break-before-make

 

Environment

Protection level
Rack mounted


IP 21

Operating temperature

0 to 40°C

Ventilation

natural cooling

Standard compliance

electromagnetic emissions EN50022 class B / class A*