> UPS systems SOCOMEC > UPS Green Power SOCOMEC

UPS Green Power SOCOMEC

GREEN POWER 2.0 (160-500 kVA/kW DELPHYS GP

The solution for

• Data centres
• Telecommunications
• Service sector
• IT Networks/ Infrastructures

Advantages

Energy Saving: high efficiency without compromise

• Offers the highest efficiency in the market using VFI – Double Conversion Mode, the only UPS working-mode that assures total load protection against all mains quality problems.
• Ultra high efficiency output independently tested and verified by an international certification organization in a wide range of load and voltage operating condition.
• Ultra high efficiency in VFI mode is provided by an innovative topology (3-Level technology) that has been developed for all the Green Power UPS ranges.

Full-rated power: kW=kVA

• No power downgrading when supplying the latest generation of servers (leading or unity power factor).
• Real full power, according to IEC 62040: kW=kVA (unity power factor design) means 25% more active power available compared to legacy UPS.
• Suitable also for leading power factor loads down to 0.9 without apparent derating.

Significant cost savings (TCO)

• Maximum energy saving thanks to 96% efficiency in true double conversion mode: 50% saving on energy losses compared to legacy UPS gives significant savings in energy bill.
• Up to 99% efficiency with FAST ECOMODE
• UPS “self-paying” with energy saving.
• Energy Saver mode for global efficiency improvement on parallel systems.
• kW=kVA means maximum power available with the same UPS rating: no overdesign cost and therefore less €/kW.
• Upstream infrastructure cost optimization (sources and distribution), thanks to high performance IGBT rectifier.

Extended battery life and performance:

• Long life battery,
• Very wide input voltage and frequency without battery use,
• EBS (Expert Battery System) charging management improves battery service life
• BHC INTERACTIVE: Accurate battery monitoring with UPS interactivity for even more prolonged service life

 

STANDARD AND OPTION FEATURES

Parallel systems

• To fulfil the most demanding needs for power supply availability, flexibility and the installation to be upgraded.
• Modular parallel configurations up to 4 MW, development without constraint.
• Distributed or centralized bypass flexibility to ensure a perfect compatibility with the electrical infrastructure.
• Twin channel architecture with Static Transfer Systems.
• Distributed or shared battery for energy storage optimization on parallel systems.

Standard electrical features

• Dual input mains.
• Integrated maintenance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.
• Redundant cooling.
• Battery temperature sensor.

Electrical options

• External maintanance bypass.
• Extended battery charger capability.
• Shared battery.
• Flywheel compatible.
• Galvanic isolation transformer.
• Backfeed isolation device.
• ACS synchronisation system.
• BHC Interactive.
• Fast EcoMode.

Standard communication features

• User-friendly multilingual interface with graphic display.
• 2 slots for communication options.
• RS232 serial port for modem.
• Ethernet connection (WEB/SNMP/MODBUS TCP/email).
• USB port for event log access.

Communication options

• Advanced server shutdown options for stand-alone and virtual servers.
• 4 additional slots for communication options.
• ADC interface (configurable voltage-free contacts).
• MODBUS/JBUS RTU.
• BACnet/IP interface
• SMS alert.

Remote monitoring service

• LINK-UPS, remote monitoring service that connects your UPS to your Critical Power specialist 24 / 7.